• 01 series.BPS160808H
  • 01 series.BPS160808H
  • 01 series.BPS160808H

01 series.BPS160808H

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(Ω) Isat(A) Itemp(A) Remarks
max. typ. max. typ. max. typ.
BPS160808H-R24M-T 0.24 0.032 0.028 4.1 4.5 3.2 3.7
BPS160808H-R47M-T 0.47 0.045 0.040 2.9 3.2 2.7 3.1
BPS160808H-R56M-T 0.56 0.059 0.052 2.7 3.0 2.4 2.8
BPS160808H-1R0M-T 1.00 0.113 0.100 2.0 2.2 1.7 2.0

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.