• 12 series.JSHC1265 series
  • 12 series.JSHC1265 series
  • 12 series.JSHC1265 series

12 series.JSHC1265 series

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)±20%
Rdc(mΩ) Isat(A) Itemp(A) SIZE
L*W*H
(mm)Max
Max. Typ. Max. Typ. Max. Typ.
JSHC1265H-R68M-GT
0.68 2.0 1.8 48.6 54 23.4 26



14.5*13.5*6.5

jshc1265h-series.pdf


JSHC1265H-1R0M-GT
1.0 3.0 2.7 44.1 49 22.5 25
JSHC1265H-1R5M-GT
1.5 3.0 2.7 40.5 45 19.8 22
JSHC1265H-2R2M-GT
2.2 4.5 4.05 36.9 41 16.2 18
JSHC1265H-3R3M-GT
3.3 8.5 7.65 25.2 28 14.4 16
JSHC1265H-4R7M-GT
4.7 14 12.6 20.25 22.5 12.6 14
JSHC1265H-6R8M-GT
6.8 15 13.5 17.1 19 10.8 12
JSHC1265H-8R2M-GT
8.2 25 22.5 15.3 17 9.0 10
JSHC1265H-100M-GT
10 25 22.5 13.95 15.5 9.0 10
JSHC1265H-150M-GT
15 38 34.2 9.0 10 5.4 6.0
JSHC1265H-220M-GT
22 44 39.6 10.8 12.0 6.3 7.0
JSHC1265H-330M-GT
33 66 59.4 6.75 7.5 3.6 4.0
JSHC1265H-470M-GT
47 90 81.0 4.5 5.0 3.15 3.5
JSHC1265H-680M-GT
68 123 110.7 4.05 4.5 2.25 2.5
JSHC1265H-101M-GT
68 165 148 2.70 3.0 2.25 2.5
JSHC1265H-121M-GT
120 250 225 2.52 2.8 1.8 2.0
JSHC1265H-151M-GT
150 280 282 2.25 2.5 1.44 1.6

Can be customized according to individual specifications.-

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.