• 02 series.MPB252010R
  • 02 series.MPB252010R
  • 02 series.MPB252010R

02 series.MPB252010R

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(Ω) Isat(A) Itemp(A) Remarks
max. typ. max. typ. max. typ.
MPB252010R-100M-T1
10
650
565
1
1.3
0.75
0.88
L:2.5±0.2 
W:2.0±0.2
H:1.0 MAX

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.