• 02 series.LPB201610D
  • 02 series.LPB201610D
  • 02 series.LPB201610D

02 series.LPB201610D

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(mΩ) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Max. Typ.
LPB201610D-R24M-T1
0.24 23.5 19.5 6.10 7.20 4.25 5.00 L:2.0±0.2 
W:1.6±0.2
H:1.0 MAX
lpb201610d产品规格书.pdf
LPB201610D-R33M-T1
0.33 27.0 22.5 5.75 6.80 4.05 4.75
LPB201610D-R47M-T1
0.47 34.0 29.5 4.90 5.80 3.65 4.20
LPB201610D-R68M-T1
0.68 43.0 36 3.65 4.30 3.10 3.65
LPB201610D-R82M-T1
0.82 53.0 45 3.50 4.10 2.80 3.30
LPB201610D-1R0M-T1
1.0 62.0 54 3.40 4.00 2.70 3.10
LPB201610D-1R5M-T1
1.5 89.0 77 2.70
3.20
2.15
2.45
LPB201610D-2R2M-T1
2.2 147.0 125 2.35 2.80 1.70 2.00
LPB201610D-3R3M-T1
3.3 200.0 170 1.70 2.00 1.35 1.60
LPB201610D-4R7M-T1
4.7 318.0 270 1.55 1.85 1.05 1.25
LPB201610D-6R8M-T1
6.8 485.0 410 1.25 1.50 0.75 0.88

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.