• 02 series.BPS201610H
  • 02 series.BPS201610H
  • 02 series.BPS201610H

02 series.BPS201610H

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(Ω) Isat(A) Itemp(A) Remarks
max. typ. max. typ. max. typ.
BPS201610H-R24M-T□
0.24 0.015
0.013 7.2 8.0 4.8 5.5
BPS201610H-R33M-T□
0.33 0.019
0.017 7.0 7.8 4.4 5.1
BPS201610H-R47M-T□
0.47 0.026

0.023

5.9 6.6 4.1 4.7
BPS201610H-R68M-T□
0.68 0.035 0.031 5.2 5.8 3.7 4.3
BPS201610H-1R0M-T□
1.0 0.046
0.041 4.6 5.1 3.4 3.9
BPS201610H-1R5M-T□
1.5 0.071 0.063 3.6 4.0 2.8 3.2
BPS201610H-2R2M-T□
2.2 0.107 0.095 3.0 3.3 2.3 2.6
BPS201610H-4R7M-T□
4.7 0.249 0.22 2.0 2.2 1.2 1.4

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.