• 02 series.BPS201608H
  • 02 series.BPS201608H
  • 02 series.BPS201608H

02 series.BPS201608H

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(Ω) Isat(A) Itemp(A) Remarks
max. typ. max. typ. max. typ.
BPS201608H-R24M-T□
0.24 0.019
0.017 5.8 6.4 4.6 5.3
BPS201608H-R33M-T□
0.33 0.025 0.022 5.6 6.2 4.2 4.8
BPS201608H-R47M-T□
0.47 0.034 0.030 4.8 5.3 3.7 4.3
BPS201608H-R68M-T□
0.68 0.046 0.041 4.2 4.6 3.3 3.8
BPS201608H-1R0M-T□
1.0 0.061 0.054 3.7 4.1 2.9 3.3
BPS201608H-2R2M-T□
2.2 0.142 0.125 2.4 2.6 1.7 2.0

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.