• 02 series.MPB252012D
  • 02 series.MPB252012D
  • 02 series.MPB252012D

02 series.MPB252012D

Universal integrated forming inductor

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(mΩ) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Max. Typ.
MPB252012D-R22M-T0
0.22
20
15
8.1
9.0
5.1
6.0
L:2.5±0.2 
W:2.0±0.2

H:1.2MAX

mpb252012d产品规格书.pdf


MPB252012D-R33M-T0 0.33 22.5 18
7.0
7.8
4.8
5.6
MPB252012D-R47M-T0
0.47
26
21.5
6.1 6.8
4.4
5.15
MPB252012D-1R0M-T0
0.62
35 25
4.5
5.0
3.5
4.1
MPB252012D-1R5M-T0 0.68
63
55
3.6
4.0 2.7
3.1
MPB252012D-2R2M-T0 2.2 86 75 3.1 3.4 2.3 2.7
MPB252012D-3R3M-T0 3.3 133 115 2.5 2.75 1.9 2.0
MPB252012D-4R7M-T0 4.7 195 170 2.1 2.25 1.5 1.75
MPB252012D-6R8M-T0
6.8
305
265
1.7
1.85
1.2
1.4
MPB252012D-100M-T0 10 414 360 1.4 1.55 0.9 1.05

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.