Part Number |
L (uH) |
Rdc(mΩ) | Isat(A) | Itemp(A) | Remarks | |||
Max. | Typ. | Max. | Typ. | Max. | Typ. | |||
MPS252010C-R24M-T |
0.24 |
32 |
25 |
4.6 |
5.8 |
3.8 |
4.5 |
L:2.5±0.2 W:2.0±0.2 H:1.0 MAX mps252010c产品规格书.pdf |
MPS252010C-R47M-T |
0.47 |
46 |
35 |
3.5 |
4.4 |
3.1 |
3.6 |
|
MPS252010C-R68M-T |
0.68 |
55 |
42 |
3.0 |
3.9 |
2.9 |
3.3 |
|
MPS252010C-1R0M-T |
1.0 |
78 |
60 |
2.7 |
3.4 |
2.5 |
3.0 |
|
MPS252010C-1R5M-T |
1.5 |
108 |
90 |
2.1 |
2.7 |
1.9 |
2.3 |
|
MPS252010C-2R2M-T |
2.2 |
156 |
130 |
1.9 |
2.4 |
1.5 |
1.8 |
|
MPS252010C-3R3M-T |
3.3 |
228 |
195 |
1.5 |
1.9 |
1.2 |
1.4 |
|
MPS252010C-4R7M-T |
4.7 |
300 |
250 |
1.3 |
1.6 |
1.0 |
1.2 |
|
MPS252010C-6R8M-T |
6.8 |
516 |
415 |
1.1 |
1.4 |
0.76 |
0.9 |
•Can be customized according to individual specifications.
•The test frequency is1MHz,OSC LEVEL:0.5V.
•Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.
•Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.
•Isat: Inductance decreases approximately from the actual initial value30%The DC current.
•Itemp: The temperature rises aboutΔT=40°CWhen the direct current.
•Depending on the circumstances of our use,ItempIs a reference value.
•In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.