Products
  • 02 series.MPS252010C
  • 02 series.MPS252010C
  • 02 series.MPS252010C
02 series.MPS252010C

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(mΩ) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Max. Typ.
MPS252010C-R24M-T
0.24
32
25
4.6
5.8
3.8
4.5
L:2.5±0.2 
W:2.0±0.2
H:1.0 MAX
mps252010c产品规格书.pdf
MPS252010C-R47M-T
0.47
46
35
3.5
4.4
3.1
3.6
MPS252010C-R68M-T
0.68
55
42
3.0
3.9
2.9
3.3
MPS252010C-1R0M-T
1.0
78
60
2.7
3.4
2.5
3.0
MPS252010C-1R5M-T
1.5
108
90
2.1
2.7
1.9
2.3
MPS252010C-2R2M-T
2.2
156
130
1.9
2.4
1.5
1.8
MPS252010C-3R3M-T
3.3
228
195
1.5
1.9
1.2
1.4
MPS252010C-4R7M-T
4.7
300
250
1.3
1.6
1.0
1.2
MPS252010C-6R8M-T
6.8
516
415
1.1
1.4
0.76
0.9

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.