Products
  • HPAC0604KS series(Automotive)
HPAC0604KS series(Automotive)

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is 100 KHz,OSC LEVEL: 1V. Can be customized according to individual specifications.


Product parameterIATF16949/AEC-Q200

Part Number Inductance Tolerance RDC(mΩ) Isat(A)  Irms(A)
(uH) (±%) Typical Max Typical Max Typical Max
HPAC0604KSR68MTG00 0.68 20 4.68 5.2 18 16.2 16 14.4
HPAC0604KS1R0MTG00 1 20 6.3 7 15 13.5 12.5 11.25
HPAC0604KS1R5MTG00 1.5 20 9.9 11 11.5 10.35 11.4 10.26
HPAC0604KS2R2MTG00 2.2 20 12.6 14 11 9.9 10 9
HPAC0604KS3R3MTG00 3.3 20 18 20 9 8.1 8 7.2
HPAC0604KS4R7MTG00 4.7 20 27 30 8.5 7.65 6 5.4
HPAC0604KS6R8MTG00 6.8 20 45 50 6 5.4 5 4.5
HPAC0604KS8R2MTG00 8.2 20 54 60 5.5 4.95 4.8 4.32
HPAC0604KS100MTG00 10 20 63 70 5.5 4.95 4.5 4.05
HPAC0604KS150MTG00 15 20 94.5 105 4 3.6 3.2 2.88
HPAC0604KS220MTG00 22 20 121.5 135 3.8 3.42 3 2.7
HPAC0604KS330MTG00 33 20 216 240 2.8 2.52 2 1.8
HPAC0604KS470MTG00 47 20 288 320 2.5 2.25 1.6 1.44

It can be customized according to individual requirements.

Operating temperature range:-55~165℃

Isat: The inductance value decreases to its initial value 30%When the DC current is loaded

Irms: The self-warming temperature of the inductor surface rises about 40℃The DC current value. ※IrmsThe reference value is based on the company's use environment