Products
  • 10 series.JSHC1050 series
  • 10 series.JSHC1050 series
  • 10 series.JSHC1050 series
  • 10 series.JSHC1050 series
  • 10 series.JSHC1050 series
10 series.JSHC1050 series

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)±20%
Rdc(mΩ) Isat(A) Itemp(A) SIZE
L*W*H
(mm)Max
Max. Typ. Max. Typ. Max. Typ.
JSHC1050H-1R0M-GT
1.0 2.8 2.52 27.0 30 16.2 18.0 11.8*10.8*3.0jshc1050h-series.pdf
JSHC1050H-1R5M-GT
1.5 6.0 5.40 19.8 22 12.6 14.0
JSHC1050H-2R2M-GT
2.2 8.5 7.65 19.35 21.5 10.8 12.0
JSHC1050H-3R3M-GT
3.3 11 9.90 14.4 16.0 9.0 10.0
JSHC1050H-4R7M-GT
4.7 17 15.3 12.6 14.0 8.1 9.0
JSHC1050H-5R6M-GT
5.6 20 18.0 11.7 13.0 7.7 8.5
JSHC1050H-6R8M-GT
6.8 25 22.5 11.34 12.6 8.1 9.0
JSHC1050H-100M-GT
10 38 34.2 9.0 10.0 5.4 6.0
JSHC1050H-150M-GT
15 50 45.0 8.1 9.0 4.5 5.0
JSHC1050H-220M-GT 22 60 54.0 6.3 7.0 4.1 4.5
JSCH1050H-330M-GT 33 105 94.5 5.4 6.0 3.2 3.5
JSCH1050H-470M-GT 47 135 121.5 3.6 4.0 2.7 3.0
JSCH1050H-680M-GT 68 250 225 3.15 3.5 2.7 3.0

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.