Products
  • 06 series.JSHC0630 series_副本
  • 06 series.JSHC0630 series_副本
  • 06 series.JSHC0630 series_副本
  • 06 series.JSHC0630 series_副本
  • 06 series.JSHC0630 series_副本
06 series.JSHC0630 series_副本

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.


Product parameter

Part Number L
(uH)±20%
Rdc(mΩ) Isat(A) Itemp(A) SIZE
L*W*H
(mm)Max
Max. Typ. Max. Typ. Max. Typ.
JSHC0630H-R22M-K 0.22 3.5 3.15 30.0 34.0 19.8 22.0 11.6*10.6*4.0

jshc0630h-series.pdf

JSHC0630H-R47M-K 0.47 5.0 4.5 18.0 20.0 16.2 18.0
JSHC0630H-R68M-K 0.68 6.0 5.4 15.3 17 12.6 14.0
JSHC0630H-1R0M-K 1.0 10 9.0 16.2 18 9.0 10.0
JSHC0630H-1R5M-K 1.5 15 13.5 13.5 15.0 8.1 9.0
JSHC0630H-2R2M-K 2.2 20 18.0 10.8 12.0 7.2 8.0
JSHC0630H-3R3M-K
3.3 30 27.0 9.0 10.0 5.4 6.0
JSHC0630H-4R7M-K
4.7 40 36.0 7.2 8.0 4.5 5.0
JSHC0630H-5R6M-K
5.6 45 40.5 6.3 7.0 4.95 5.5
JSHC0630H-8R2M-K
8.2 70 63.0 4.95 5.5 3.6 4.0
JSHC0630H-100M-K
10 68 61.2 4.5 5.0 3.6 4.0
JSHC0630H-120M-K
12 130 117 3.6 4.0 2.61 2.9
JSHC1040H-150M-K 15 130 117 3.6 4.0 2.7 3.0
JSHC0630H-220M-K
22 150 135 2.7 3.0 2.25 2.5
JSHC0630H-330M-K
33 240 216 2.25 2.5 1.8 2.0
JSHC0630H-470M-K
47 385 346.5 1.8 2.0 1.35 1.5
JSHC0630H-R15M-GT
0.15 1.0 0.9 41.4 46 33.3 37.0
JSHC0630H-R22M-GT
0.22 2.3 2.07 36.0 46.0 23.4 26.0
JSHC0630H-R33M-GT
0.33 3.9 3.51 27.0 30.0 18.0 20.0
JSHC0630H-R47M-GT
0.47 4.5 4.05 23.4 26.0 15.75 17.5
JSHC0630H-R68M-GT
0.68 6.0 5.4 22.5 25 12.6 14.0
JSHC0630H-1R0M-GT
1.0 10 9.0 19.8 22.0 9.9 11.0
JSHC0630H-1R5M-GT 1.5 15
13.5 16.2 18.0 8.1 9.0
JSHC0630H-2R2M-GT
2.2 20 18 12.6 14.0 7.2 8.0
JSHC0630H-3R3M-GT 3.3 30 27 9.0 10.0 5.4 6.0
JSHC0630H-4R7M-GT 4.7 40 36 9.0 10.0 4.95 5.5
JSHC0630H-5R6M-GT 5.6 60 54 6.3 7.0 4.5 5.0
JSHC0630-6R8M-GT 6.8 60 54 6.3 7.0 4.05 4.5
JSHC0630-100M-GT 10 110 99 5.4 6.0 2.7 3.0

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.