Products
  • 02 series.MPB201610D
  • 02 series.MPB201610D
  • 02 series.MPB201610D
02 series.MPB201610D

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(Ω) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Max. Typ.
MPB201610D-R24M-TW0
0.24 25
20
6,5
7.05
4.8
5.6
L:2.0±0.2 
W:1.6±0.2
H:1.0 MAX
mpb201610d产品规格书.pdf
MPB201610D-R47M-TW0
0.47 33
27
5.1
5.65
4.3
5.1
MPB201610D-1R0M-TW0
1.0 54 45 3.7 4.05 2.9 3.4
MPB201610D-1R5M-TW0
1.5 76
66
2.9
3.30
2.3
3.4
MPB201610D-2R2M-TW0
2.2 125
108
2.3
2.6
1.7
2.1
MPB201610D-4R7M-TW0
4.7 270
235
1.7
1.9
1.1
1.3

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.