Products
  • 02 series.MPB201610P
  • 02 series.MPB201610P
  • 02 series.MPB201610P
02 series.MPB201610P

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(mΩ) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Tax. Typ.
MPB201610P-R24M-T1
0.24 23.5 19.5 6.10 7.2 4.25 5.0 L:2.0±0.2 
W:1.6±0.2
H:1.0 MAX
mpb201610p产品规格书.pdf
MPB201610P-R33M-T1
0.3 27 22.5 5.75 6.8 4.05 4.75
MPB201610P-R47M-T1
0.47 34 29.5 4.90 5.8 3.65 4.2
MPB201610P-R68M-T1
0.68 43 36 3.65 4.3 3.1 3.65
MPB201610P-R82M-T1
0.82 53 45 3.50 4.1 2.8 3.3
MPB201610P-1R0M-T1
1.0 62 54 3.40 4.0 2.7 3.1
MPB201610P-1R5M-T1
1.5 89 77 2.70 3.2 2.15 2.45
MPB201610P-2R2M-T1
2.2 147 125 2.35 2.8 1.7 2.0
MPB201610P-3R3M-T1
3.3 200 170 1.70 2.0 1.35 1.60
MPB201610P-4R7M-T1
4.7 318 270 1.55 1.85 1.05 1.25
MPB201610P-6R8M-T1
6.8 485 410 1.25 1.5 0.75 0.88

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.