Products
  • 02 series.LPB252012D
  • 02 series.LPB252012D
  • 02 series.LPB252012D
02 series.LPB252012D

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement. The test frequency is1MHz,OSC LEVEL:0.5V. Can be customized according to individual specifications.

Product parameter

Part Number L
(uH)
Rdc(mΩ) Isat(A) Itemp(A) Remarks
Max. Typ. Max. Typ. Max. Typ.
LPB252012D-R22M-T0
0.22
20
15
8.1
9.0
5.1
6.0
L:2.5±0.2 
W:2.0±0.2

H:1.2 MAX

lpb252012d产品规格书.pdf


LPB252012D-R33M-T0
0.33
23 18
7.0
7.8
4.8
5.6
LPB252012D-R47M-T0
0.47
26
21.5
6.1
6.8
4.4
5.15
LPB252012D-1R0M-T0
1.0
42
35
4.5
5.0
3.5
4.1
LPB252012D-1R5M-T0
1.5
63
55
3.6
4.0 2.7
3.1
LPB252012D-2R2M-T0
2.2
86
75
3.1
3.4
2.3
2.7
LPB252012D-3R3M-T0
3.3
133
115
2.5
2.75
1.9
2.2
LPB252012D-4R7M-T0
4.7
195
170
2.1
2.25
1.5
1.75
LPB252012D-6R8M-T0
6.8
305
265
1.7
1.85
1.2
1.4
LPB252012D-100M-T0
10
414
360
1.4
1.55
0.9
1.05

Can be customized according to individual specifications.

The test frequency is1MHz,OSC LEVEL:0.5V.

Inductance functionKeysight Technologies LCRMeasuring instrument4285AMeasured. The same measurement equipment can be used for the same measurement.

Inductance value: The inductance value decreases approximately from the actual initial value30%When the direct current.

Isat: Inductance decreases approximately from the actual initial value30%The DC current.

Itemp: The temperature rises aboutΔT=40°CWhen the direct current.

Depending on the circumstances of our use,ItempIs a reference value.

In the final application, the circuit should be designed so that the temperature rise of the component does not exceed40℃.